|
From 1999 when Charles Cressy first developed, introduced and patented a drying assembly method and over the following 14 years convectant drying has been further developed and become established as an alternative to conventional refrigerant and desiccant dehumidifier drying techniques. The process is revolutionising how wet property is dried out as it minimizes stripout, secondary damage and downtime. In July 2013 British Standards PAS 64 "Mitigation and recovery of water damaged buildings - Code of practice" was published recognising and including descriptions of the process within the document. The PAS 64:2013 is available for purchase (www.bsigroup.com/shop) Convectant drying is described as: "the balanced manipulation and control of air exchanges, heat, and vapour pressure differential to create optimum conditions for evaporation, reduction and control of airborne moisture from the indoor environment". The word "convectant" was coined by A Habbershaw and TJ Cressy in 2003 so that the process could be recognised and established as a credible alternative to the traditional refrigerant and desiccant drying processes. The convectant drying process has been independently tested by the National Flood School in the UK (2005 and 2012) this testing confirmed the efficacy of the process which has been proven to be many times faster than traditional drying methods. Convectant drying equipment is available in portable and trailer mounted form. The method has been granted international patents. US Patent 6662467: U.S. Provisional Application No. 61/194,062, US20100011612 and for a portable hand truck method. Also, a GB Patent No 0813169.0. Both systems use heat, air exchanges and controlled manipulation of the indoor environment to reduce the drying time compared to traditional methods. ==Method of operation== The temperature in the target area is increased by recirculating its air through the machine's conditioning system. The system heats and lowers the relative humidity of the air being conditioned. The conditioned air is fed into the target drying area either directly or through ducts. The structure gradually warms up and vapor pressure is lowered - promoting evaporation. Evaporated water increases the relative humidity in the drying area. This could result in evaporation ceasing if saturation is achieved and secondary damage to the target area or to other areas of the property not originally damaged. So, to deal with this the process can either switch to exhaust mode in the portable systems, expelling the wet air to the outside or repeatedly venting the air to the outside via a heat exchanger in the trailer process. As wet air is expelled and at the same time, outside fresh air in equal amounts is drawn into the systems conditioning system and it is then introduced back into the room to repeat the process until the property is dry. A dry state is determined when the exhaust specific humidity drops below intake specific humidity at which stage the heater and machines air exchange fans are automatically turned off and the technician notified by email or text that the building is dry. Unlike traditional dehumidifiers, convectant systems work efficiently across all temperature ranges. 抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)』 ■ウィキペディアで「Convectant drying」の詳細全文を読む スポンサード リンク
|